PART 1 – VARIATION OF INDUCTOR
Follow the steps:
Select More Topologies
Select Buck DC- DC
Please note that the power ratings may differ as components are updated by supplier.
Select the “LOSS” tab in the TOOLS section on the left of page.
The “Input and Output Opertaing Conditions” pop up will appear
Select “T1”. The “Magnetic Builder” pop up will appear.
Change the number of turns No to 10 and press ‘done’.
The “Input and Output Opertaing Conditions” pop up will re appear. Note the “Total Losses” value has changed.
Q1 After following the steps above, change the number of turns on T1 to 15 and:
Supply a screen shot of the Magnetic Builder details
Write the TOTAL LOSS value
Write the XFormer LOSS value
Write the Bm value
Screenshot the Input and Output Operating Conditions.
Q2 After following the steps above, change the number of turns on T1 to 30 and:
Supply a screen shot of the Magnetic Builder details
Write the TOTAL LOSS value
Write the XFormer LOSS value
Write the Bm value
Screenshot the Input and Output Operating Conditions
Q3 After following the steps above, change the number of turns on T1 to 60 and:
Supply a screen shot of the Magnetic Builder details
Write the TOTAL LOSS value
Write the XFormer LOSS value
Write the Bm value
Screenshot the Input and Output Operating Conditions
Q4 After following the steps above, change the number of turns on T1 to 80 and:
Supply a screen shot of the Magnetic Builder details
Write the Bm value
Screenshot the Input and Output Operating Conditions
PART 2 – VARIATION OF CAPACITOR
After following steps 1 to 5 as above in part 1;
Select “C4” - The “Component Selector” pop up will appear
Note the value of C4 is 2.2 µF 50 Vdc. C4 can be changed by highlighting and double clicking on the selection.
Press “Done”. The “Input and Output Operating Conditions” pop up will re appear.
12: Record the “Total Losses” value.
Q5 Following the steps above:
Change the number of turns on T1 to 15
Change the C4 to 1.5 µF 50 VDC
Supply a screen shot of the Component Selector details
Write the TOTAL LOSS value
Supply a screenshot of the Input and Output Operating Conditions
Q6 Following the steps above:
Change the C4 to 3.3 µF 50 VDC
Supply a screen shot of the Component Selector details
Write the TOTAL LOSS value
Supply a screenshot of the Input and Output Operating Conditions
This Engineering Assignment has been solved by our Engineering experts at My Uni Papers. Our Assignment Writing Experts are efficient to provide a fresh solution to this question. We are serving more than 10000+ Students in Australia, UK & US by helping them to score HD in their academics. Our Experts are well trained to follow all marking rubrics & referencing style.
Be it a used or new solution, the quality of the work submitted by our assignment experts remains unhampered. You may continue to expect the same or even better quality with the used and new assignment solution files respectively. There’s one thing to be noticed that you could choose one between the two and acquire an HD either way. You could choose a new assignment solution file to get yourself an exclusive, plagiarism (with free Turnitin file), expert quality assignment or order an old solution file that was considered worthy of the highest distinction.