Group Assignment 1:
Daily inlet flow : 2.45 MLD
Peak daily flow : 2.7 MLD
Influent parameter concentrations
Parameter Unit Peak
COD mg/L 2000
TKN mg/L 230
TP mg/L 70
TSS mg/L 500
Alkalinity mgCaCO3/L 1000
Outlet desired concentrations
Parameter Units Performance requirements
Flow L/s 80
Flow ML/d 2.7
COD removal `
Total Phosphorous min mg/L 8 to 10
Alum dose typical range mg/L 100 to 1200
Total Suspended Solids max mg/L 50
Effluent alkalinity mgCaCO3/L 500
Into that Lamella Plate clarifier :
500 mg/L Alum is dosed @ 200 L/hr
150 mg/L Caustic is dosed @ 124 L/hr
7 mg/L Polymer is dosed @ 4.5 L/hr
To achieve the required performance.
Do the sizing of Lamella plate clarifier (propose no. of plates) in excel sheet, explain the process, indicate the dimensions on a simple drawing handmade scanned copy is also ok (I only need excel file).
This Engineering Assignment has been solved by our Engineering Experts at My Uni Papers. Our Assignment Writing Experts are efficient to provide a fresh solution to this question. We are serving more than 10000+Students in Australia, UK & US by helping them to score HD in their academics. Our Experts are well trained to follow all marking rubrics & referencing style.
Be it a used or new solution, the quality of the work submitted by our assignment Experts remains unhampered. You may continue to expect the same or even better quality with the used and new assignment solution files respectively. There’s one thing to be noticed that you could choose one between the two and acquire an HD either way. You could choose a new assignment solution file to get yourself an exclusive, plagiarism (with free Turnitin file), expert quality assignment or order an old solution file that was considered worthy of the highest distinction.
© Copyright 2026 My Uni Papers – Student Hustle Made Hassle Free. All rights reserved.